TM 9-2350-260-20-1-2 AIR CLEANER (ARMORED) BLOWER FAN REPLACEMENT (Sheet 5 of 7) 4. Connect jumper lead (E) to short lead from blower fan (F). 5. Position blower fan (F) into housing (with exhaust outlet of blower facing exhaust elbows) onto support. 6. Position strap (G) over blower fan (F). 7. Install two screws and new lockwashers (H) to secure strap (G) to support 8. Using socket with extension, tighten screws (H). 9. Connect long lead (J) from blower fan (F) to ground lead connector (K). Go on to Sheet 6 TA148220 7-145