TM 9-2350-260-20-1-2 POWERPLANT REPLACEMENT (2D ENGINE) (Sheet 6 of 26) NOTE Clamps (R) may require flat-tip screwdriver for removal. 13. Using 7/16 inch wrench, remove two nuts holding two clamps (R) to two air cleaner outlet hoses (S) on each side of powerplant. Remove hoses. 14. Put protective covering over air cleaner outlet elbow (T) and turbocharger elbow (T) on each side of powerplant. NOTE One angle bracket (U) is located on each side at rear of tank. 15. Using 9/16 inch socket with 2 inch extension, remove three screws), lockwashers (W), and washers (X) securing each angle bracket (U). Throw lockwashers away. 16.Lift up rear corner of bracket (U) to remove it. Go on to Sheet 7 TA147932 5-31