TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download
Page 409 of 772
TM 9-2350-280-201-2 AIR CLEANER (ARMORED) BLOWER FAN GROUND LEAD REPLACEMENT (Sheet 2 of 2) INSTALLATION: 1. Connect two connectors (A) to blower leads (W). 2. Install screw (C) and two new lockwashers (D) to secure ground lead (E) terminal to boss (F). 3. Using socket, tighten screw (C). 4. Install air cleaner cover and gasket (page 7-150, steps 3 thru 7). 5. Check operation of blower (TM 9-2350-260-10). End of Task TA148215 7-140