TM 9-2350-260-20-1-2 AIR CLEANER (ARMORED) BLOWER FAN GROUND LEAD REPLACEMENT (Sheet 1 of 2) TOOLS: 7/16 in. socket with 1/2 in. drive Ratchet with 1/2 in. drive 10 in. extension with 1/2 in. drive REFERENCE: TM 9-2350-260-10 PRELIMINARY PROCEDURE: Remove air cleaner cover and gasket (page 7-149, steps 1 thru 4) REMOVAL: 1. Disconnect two connectors (A) from blower leads (B). 2. Using socket, remove screw (C) and two lockwashers (D) securing ground lead (E) to boss (F). Throw lockwashers away. Go on to Sheet 2 TA148214 7-139