TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download
Page 403 of 772
TM 9-2350-260-20-1-2 AIR CLEANER (ARMORED) CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 1) TOOLS: Cross-tip screwdriver SUPPLIES: Lockwasher (MS35338-41) (4 required) REFERENCE: TM 9-2350-260-10 PRELIMINARY PROCEDURE: Remove air cleaner cover and gasket (page 7-149, steps 1 thru 4) NOTE All air cleaner circuit breakers are removed and installed the same. REMOVAL: 1. Using screwdriver, remove screws (A) and lockwashers (B) securing circuit breaker (C) to cover (D). Throw lockwashers away. 2. Remove circuit breaker (C). 3. Disconnect two electrical leads (circuit 415). INSTALLATION: 1. Position circuit breaker (C) onto cover (D). 2. Install new lockwashers (B) and screws (A) to secure circuit breaker (C) to cover (D). Using screwdriver, tighten screws (A). 3. Connect two electrical leads (circuit 415). 4. Install cover and gasket (D) (page 7-150, steps 3 thru 7). 5. Check operation of blowers (TM 9-2350-260-10). End of Task TA148209 7-134