TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download
Page 398 of 772
TM 9-2350-260-20-1-2 AIR CLEANER (ALUMINUM AND SIDE LOADING) BLOWER FAN REPLACEMENT (Sheet 5 of 6) INSTALLATION: 1. Position pad (A) and bracket (B) in housing. 2. Coat threads of two screws (C) with sealer (Item 53, Appendix D), and install two screws (C, new lockwashers (D), and flat washers (E) to secure bracket (B). 3. Using 9/16 inch socket, tighten screws (C). 4. Connect jumper lead (F) to longer blower lead. 5. Position blower (G) into bracket (B). 6. Position bracket (B) around blower (G) and install two screws (H), new lockwashers (J), and flat washers (K) to secure band. 7. Using 1/2 inch socket, tighten screws (H). 8. Connect short electrical lead (L) of blower to ground lead. 9. Connect hose (M) to inlet port of blower (G). 10. Slide hose clamp (N) over hose (M) and inlet port of blower (G). 11. Using screwdriver, tighten nut of clamp (N). Go on to Sheet 6 TA148204 7-129