TM 9-2350-260-20-1-2 AIR CLEANER FILTER ASSEMBLY REPAIR AND REPLACEMENT (SIDE LOADING) (Sheet 1 of 5) PROCEDURE INDEX PROCEDURE PAGE Removal 7-106 Disassembly 7-107 Cleaning and Inspection 7-108 Assembly 7-109 Installation 7-109 TOOLS: 9/16 in. socket with 1/2 in. drive Ratchet with 1/2 in. drive Slip joint pliers SUPPLIES: Low pressure air system Liquid detergent (Item 33, Appendix D) Rags (Item 65, Appendix D) Lockwasher (MS35333-38) (2 required) NOTE Two types of side loading air cleaners are found on M60 tanks. If your tank has type (A), start with step 1. If your tank has type (B), skip steps 1 and 2, go on to step 3. REMOVAL: NOTE Replacement and repair of air cleaner filter assembly is the same for left or right side. Left side shown. 1. Using 9/16 inch socket, remove two screws, lockwashers, and flat washers (C) securing door (D). Throw lockwashers away. 2. Open door (D) and go to step 5. 3. Using 9/16 inch socket, remove screw and flat washer (E) securing handle (F). 4. Using handle (F), open door (G. Go on to Sheet 2 TA148181 7-106