TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download
Page 373 of 772
TM 9-2350-260-20-1-2 AIR CLEANER DOOR REPLACEMENT (TOP LOADING) (Sheet 2 of 2) REPAIR: 1. Inspect screws (A) and gasket (B). 2. If gasket (B) is damaged in any way, replace it. 3. Apply sealing compound (Item 24, Appendix D), on new gasket (B). Install gasket into groove at underside of door (C). 4. Replace decal (D), as necessary. Install decal so It can be read from center of tank. INSTALLATION: NOTE Check three door bolts and bolt holes on top of air cleaner. If bolt threads are stripped, replace bolts. If holes are not drilled through, use compressed air to remove sand, dirt, or debris from holes. 1. Lift door assembly (A) into place on air cleaner housing (B). 2. Using hammer, tap three pins (C) into three hinges (D). 3. Install three flat washers (E) onto three pins (C). 4. Using hammer, tap three new cotter pins (F) into holes in pins (C). 5. Using hammer, tap cotter pins around straight pins (C) to secure washers (E) and pins in place. 6. Apply thin film of sealing compound (Item 22, Appendix D) to gasket mating surface of housing. 7. Make sure door assembly (A) is in closed position (lowered). 8. Using wrench, tighten three screws (G) to secure door (A) to air cleaner housing (B). WARNING Compressed air used for cleaning purposes will not exceed 30 psi. Use only with effective chip guarding and personal protective equipment (goggles/shield, gloves, etc.). End of Task TA148179 7-104