TM 9-2350-260-20-1-2 AIR CLEANER DOOR REPLACEMENT (TOP LOADING) (Sheet 1 of 2) TOOLS: 9/16 in. combination box and open end wrench Long round nose pliers Hammer (or mallet) Slip joint pliers Low pressure compressed air source SUPPLIES: Gasket (12251909) Cotter pins (MS24665-285) (3 required) Sealing compound (Item 22, Appendix D) Sealing compound (Item 24, Appendix D) REMOVAL: NOTE If captive screws are used, they will only be loosened and not removed. 1. Using wrench, remove three screws and washers (A). 2. Using pliers, remove three cotter pins (B). 3. Using pliers, pull three cotter pins (B) out of three pins (C). Throw cotter pins away. 4. Remove flat washers (D). 5. Using hammer, tap straight pins (C) free of door hinges (E). 6. Using pliers, pull three pins (C) from door hinges. 7. Lift door assembly (F) and remove it from air cleaner housing (G). NOTE Procedures for replacement of door for aluminum and armored air cleaner are the same. Go on to Sheet 2 TA148178 7-103