TM 9-2350-260-20-1-2 AIR CLEANER INTAKE ELBOW REPLACEMENT(Sheet 3 of 3) INSTALLATION: 1. Position new gasket (A) onto studs of air cleaner. 2. Install elbow (B) onto studs of air cleaner. 3. Install ten new self-locking nuts (C) onto studs to secure elbow (B) to air cleaner. 4. Using socket or 9/16 inch wrench, tighten ten nut (C). 5. Install hose (D) onto elbow (B). 6. Slide clamp (E) up over hose () and onto elbow (B). 7. Using 3/8 inch wrench, tighten clamp nut (F) to secure clamp (E). 8. Close top deck grille doors (TM 9-2350-260-10). End of Task TA148156 7-81