TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download

Page 347 of 772

TM 9-2350-260-20-1-2 AIR CLEANER (LEFT AND RIGHT) RESTRICTION INDICATOR REPLACEMENT (Sheet 1 of 1) TOOLS: 7/16 in. combination box and open end wrench Slip joint pliers NOTE Replacement of restriction indicator is the same for all air cleaners. Aluminum air cleaner is shown. REMOVAL: 1. Using wrench, remove restriction indicator (A). 2. Remove plug (B) from side of guard (C) and thread plug into threaded hole where restriction indicator was. 3. Using pliers, open hooks (D) and replace hooks (D), chain (E), or plug (B), as necessary. INSTALLATION: 1. Remove plug (B) from restriction indicator mounting hole. 2. Install restriction indicator (A). Using wrench, tighten restriction indicator. 3. Thread plug (B) into threaded hole on side of guard (C). End of Task TA148158 7-78