TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download
Page 329 of 772
TM 9-2350-260-20-1-2 FUEL PUMP REPLACEMENT - LEFT FUEL TANK (Sheet 9 of 9) 16. Install electrical lead (AK) to connector (AL). 17. Turn fuel isolate valves back to original position (TM 9-2350-260-10). 18. Fill fuel tank. 19. Install 2A powerplant (page 5-14) or 2D powerplant (page 5-40). End of Task TA148135 7-60