TM 9-2350-260-20-1-2 PURGE FUEL SYSTEM (2A ENGINE) (Sheet 2 of 3) PURGING: 1. Turn MASTER CONTROL switch OFF. 2. Place rags (Item 65, Appendix D) and container under secondary fuel filter (A) or fuel water separator (A). 3. Using wrench and flashlight, reach through access hatch and loosen bleed cap (B). 4. Operate primer pump handle (TM 9-2350-260-10). 5. Observe for air bubbles coming from secondary fuel filter or fuel water separator bleed cap (B). 6. Operate primer pump handle until constant fuel flow is observed from bleed cap (B). 7. Using wrench, close bleed cap (B). Go on to Sheet 3 TA148083 7-8