TM-9-2350-260-20-1-2 M60 Hull Organizational Maintenance Volume 2 Download

Page 234 of 772

TM 9-2350-260-20-1-2 ENGINE OIL COOLER FLUID PUMP CONNECTOR REPLACEMENT (2D ENGINE) (Sheet 4 of 4) 5. Using two 1-1/2 inch wrenches, install hose (E) to fitting (F). 6. Using screwdriver and 3/8 inch wrench, install clamp (G) on hose (E) if removed during disassembly. 7. Position new sealing washer (H) over vent hole. 8. Using 9/16 inch wrench, install vent bolt (J) through washer (H). 9. Using socket and torque wrench, tighten drain valve (K) to a minimum of 150 lb-in (17 Nm). Do not overtighten. 10. Perform ground hop (page 5-57). Run engine at idle until oil temperature is in normal operating range (TM 9-2350-260-10). 11. Check oil level. Add oil as required (LO 9-2350-260-12. 12. Disconnect ground hop kit (page 5-67). 13. Install powerplant (page 5-40). End of Task 6-157