TM 9-2350-260-20-1-2 POWERPLANT REPLACEMENT (2A ENGINE) (Sheet 10 of 24) NOTE When removing screw (AP), hold onto quick- disconnect ring (AQ), or it will snap open and fall down into engine compartment. 36. Using 3/4 inch socket, remove screw (AP) securing quick-disconnect ring (AQ). 37. Remove both rings (AQ). 38. Using hammer and pinch bar, tap final drive adapter (AR) toward final drive each side of tank far enough to free adapter from universal joint. NOTE Continue tapping final drive adapter (it will move 1-1/2 inches) until gears release. 39. Hang two fabricated final drive guide shields (Fig. 1, Appendix F) (one on each side of tank) at final drive universal joints (AS) to prevent hangups when powerplant is removed. Go on to Sheet 11 TA147912 5-11