TB-9-2300-378-14 Technical Bulletin for Air Induction System M48 M60 Download

Page 53 of 296

5. 6. 7. 8. Check turbo elbow and tight (view B). Check turbo elbow TB 9-2300-378-14 flange to ensure that all studs, and nuts are present, for gasket between turbo elbow, and turbo housing. Inspect gasket as much as possible looking for tears, folds, and missing pieces using an inspection mirror, and flashlight where necessary. Inspect connection of outlet hose to outlet elbow (view C). Check that band clamp is installed. Inspect clamp for damage, or missing parts (i.e., bent, broken, or missing fingers, torn band, broken finger pivot mounts). Replace defective hose or clamp. Refer to para. 3-6b. Verify that all fingers engage outlet elbow flange (view D). Use inspec- tion mirror and flashlight to view bottom fingers. Grasp each finger individually, and attempt to move it side to side. Movement of any finger indicates a loose clamp. Tighten clamp if loose. Attempt to rotate flat band clamp, located on hose just behind finger band clamp. Any movement indicates a loose clamp. Tighten clamp if loose. (b) V-Band Clamps (Fig. 3-10). Figure 3-10. Air outlet hose inspection (V-band clamp). NOTE If V-band clamps, and V-band clamps with quick release handle are installed instead of the finger band clamps, perform steps 1 thru 7. 3-33