TB-9-2300-378-14 Technical Bulletin for Air Induction System M48 M60 Download

Page 48 of 296

TB 9-2300-378-14 NOTE A suitable washing vat can be fabricated using the following suggested procedures: (a) (b) (c) Obtain a 55 gallon drum, approximately 23 inch diameter and 34 inch high. Thoroughly clean out drum (steam clean). Remove one end of drum (preferably the end with plugs in it). Minimum height of drum must be 23 inches. Obtain a length of 5/8 or 3/4 inch water hose sufficient to cover cut edges of drum. (d) (e) Split water hose lengthwise and position on cut edge of drum. This will prevent filter element damage from the cut edge. 3-5. Final Drive and Fuel Tank Vent Systems Inspection. a. Fuel Tank Vent System (Fig. 3-6). Figure 3-6. Fuel tank vent system inspection. 3-28