MWO-9-2300-378-34-2 Maintenance Work Order for M60 Smoke Generation Download
Page 29 of 92
MW09-2300-378-34-2 (8) Drain fuel/water separator (refer to appropriate vehicle TM) (9) Disconnect fuel outlet hose from bottom of fuel/water separator existing outlet elbow 10935536 (figure 17, view A). (10) Remove and discard fuel/water separator existing outlet elbow 10935536 (figure 17, view A). (11) Apply teflon tape on tee AN825-8 and install tee in fuel/water separator outlet port (figure 17, view B). (12) Connect fuel outlet hose to tee AN825-8 (figure 17, view B). (13) Connect hose assembly MS28741-8-0194 to tee AN825-8 and to manual shut-off valve (figure 17, view B). (14) position tube assembly 12275811 under electrical harnesses and along left engine access covers (figure 18). (15) connect tube assembly 12275811 to manual shut-off valve 45° elbow and to shroud elbow (figure 18). A 11/16-inch open-end box wrench will be required to tighten tube assembly to shroud elbow. (16) Remove and retain screws and lockwashers (from positions, 2 and 6, figure 18) securing engine access covers. (17) Install clamps MS21333-111 on tube assembly at positions 2 and 6 (figure 18). Secure clamps and engine access cover with screws and lockwashers removed in step 16. 27