LO-5-5420-202-13 Lubrication Order for M48A5 M60A1 BRIDGE LAUNCHER AVLB Download

Page 8 of 28

LO 5-5420-202-13 Card 8 of 22 NOTES: 4. SMOKE GRENADE LAUNCHERS. a) Before Firing: Wipe all surfaces dry. b) After Firing: Immediately clean with CLP (MIL-PRF-63460) and wipe dry. Apply a light coat of CLP to all surfaces. Make sure all surfaces are coated. Do not wipe dry. After firing, repeat process for 2 days. c) Inactivity: If not to be fired for an extended period, quarterly, clean with CLP, wipe dry and apply CLP (MIL-PRF-63460) to all surfaces. d) Do not lubricate contacts at bottom of tubes. WARNING FRH fluid may cause irritation to the eyes and skin. Avoid contact with eyes, skin, and clothing. Wear protective goggles, gloves, and clothing. If FRH fluid comes in contact with eyes or skin, flush the area with water. Failure to comply may result in injury or illness to personnel. Cleaning Compound (MIL-PRF-680) is flammable and may cause irritation to the eyes or skin. Use in well ventilated areas and keep away from heat and open flames. Wear protective goggles, gloves, and clothing. If compound comes in contact with eyes, flush immediately with water. If compound comes in contact with skin, wash with soap and water. Failure to comply may result in injury, illness or death to personnel. 5. HYDRAULIC BREATHER FILTER. Remove cap. Clean filter with cleaning compound (MIL-PRF-680) and dry by shaking. Oil the filter using FRH fluid (MIL-PRF-46170). Do not use OE/HDO oil. In extremely dusty conditions, service more frequently. Every month, remove breather tube, clean with cleaning compound, and dip in FRH fluid. Do not use OE/HDO oil.