LO-5-5420-202-13 Lubrication Order for M48A5 M60A1 BRIDGE LAUNCHER AVLB Download
Page 11 of 28
LO 5-5420-202-13 Card 11 of 22 NOTES: WARNING Cleaning Compound (MIL-PRF-680) is flammable and may cause irritation to the eyes or skin. Use in well ventilated areas and keep away from heat and open flames. Wear protective goggles, gloves, and clothing. If compound comes in contact with eyes, flush immediately with water. If compound comes in contact with skin, wash with soap and water. Failure to comply may result in injury, illness or death to personnel. Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only with effective chip-guarding and personal protective equipment (goggles/faceshield, gloves, etc.). Failure to comply may result in injury to personnel. 9. TRANSMISSION OIL FILTER. Remove element. Clean with cleaning compound (MIL-PRF-680). Dry with compressed air. Inspect for damage and replace, if defective. Install element. 10. To drain transmission, remove two drain plug access plates from bottom of hull and remove drain plugs. After draining, clean and install drain plugs and access plates. Refill transmission to ADD mark on dipstick. Follow transmission oil check procedure in Note 3. 11. TRANSMISSION SIDE OIL SCREEN. Whenever powerplant is removed and transmission is drained, remove, clean, inspect, and install the side oil screen.