TM 9-2910-226-34 (2) Refer to figure 3-55. Remove outer spring spacer (A), inner spring spacer (B), governor outer spring (C), governor inner spring (D), and pipe plug (E). (4) Refer to figure 3-57. Remove oil baffle (A) and sliding sleeve (B). Figure 3-55. Removing inner and outer springs and spacers. NOTE Paragraph (3) applies only to code A in- jection pumps. (3) Refer to figure 3-56. Unhook torque link spring (A) from torque link (B) and oil baffle (C) and remove spring. Figure 3-57. Removing oil baffle and sliding sleeve. NOTE The operating lever on code A pumps and early code G pumps is a one-piece lever; all others are two-piece. Discard all one-piece levers on early code G pumps and replace with two-piece lever. (5) Refer to figure 3-58 or 3-59. Remove the lead seal (A). Remove machine bolts (B), lockwashers (C) and dust cover (D). Remove nut (E), lockwasher (F), and clamping screw (G). Remove operating lever (H). Figure 3-56. Removing torque link spring (Code A pumps). 3-39