TM-9-2815-210-34-2-2 Page 615

TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2

Page 615 of 968

TM 9-2815-210-34-2-2 FRAME 3 1. 2. 3. 4. 5. 6. Turn on rheostat (1) until voltmeter (2) reads 24 volts. Turn on adjustable valve (3) until pressure gage (4) reads 5 to 10 psi. Check that nozzle and valve assembly (5) inlet (6) and outlet (7) do not leak. Get a new nozzle and valve assembly if inlet and outlet leak. Turn off adjustable valve (3). Turn off rheostat (1). Take off nozzle and valve assembly (5). END OF TASK 4-596