TM-9-2815-210-34-2-2 Page 611

TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2

Page 611 of 968

TM 9-2815-210-34-2-2 FRAME 3 CAUTION 1. 2. Hook up Hook up Flame heater fuel pump electrical system is negative grounded. Pin A positive and pin B is negative. Do not switch polarity of pump during checking or replace- ment. Changing polarity will permanently damage pump. 24-volt battery (1) with rheostat (2) to fuel pump receptacle. voltmeter (4) to fuel pump receptacle (3). GO TO FRAME 4 4-592