TM-9-2815-210-34-2-2 Page 610

TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2

Page 610 of 968

TM 9-2815-210-34-2-2 FRAME 2 1. Hook up 2. Hook up 3. Hook up 4. Hook up NOTE This is an alternate procedure given for reference purposes only. Standard procedure is to test flame heater nozzle during dynamometer test and adjust- ment. hose (1) from supply tank (2) of diesel fuel to pump inlet (3). hose (4) from pump outlet (5) to pressure gage (6). adjustable valve (7) from pressure gage (6). hose (8) from adjustable valve (7) to nozzle and valve assembly (9) inlet opening (10). GO TO FRAME 3 4-591