TM-9-2815-210-34-2-2 Page 584

TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2

Page 584 of 968

TM 9-2815-210-34-2-2 d. Leak Test. WARNING Smoking, sparks or open flames are not allowed within 50 feet of work area during this task. Fire or explosion could occur, causing injury to personnel and damage to equipment. NOTE This is an alternate procedure given for ref- erence purposes only. Standard procedure is to test for leaks during dynamometer test and adjustment. FRAME1 1. 2. 3. 4. GO Hook up hose (1) from a supply (2) of diesel fuel to pump inlet (3). Hook up hose (4) from pump outlet (5) to adjustable valve (6). Hook up pressure gage (7) from adjustable valve (6). Hook up hose (8) from pressure gage (7) to nozzle and check valve assembly (9), inlet (10), and outlet (11). TO FRAME 2 4-565