TM-9-2815-210-34-2-2 Page 582

TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2

Page 582 of 968

TM 9-2815-210-34-2-2 FRAME 3 CAUTION 1. Hook up 2. Hook up The flame heater fuel pump electrical system is negatively grounded. Pin A is positive and pin B is negative. Do not switch polarity of pump during checking or replace- ment. Changing polarity will permanently damage pump. 24-volt battery (1) with rheostat (2) to fuel pump receptacle (3). voltmeter (4) to fuel pump receptacle (3). GO TO FRAME 4 4-563