TM-9-2815-210-34-2-2 Page 570

TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2

Page 570 of 968

TM 9-2815-210-34-2-2 4-65. FLAME HEATER IGNITION UNIT (COVERED SYSTEM). a. Cleaning. (1) Cap receptacle openings on ignition unit. WARNING Dry cleaning solvent inflammable. Do not use near an open flame. Keep a fire extinguisher nearby when solvent is used. Use only in well- ventilated places. Failure to do this may result in injury to personnel and damage to equipment. CAUTION Ignition unit should not be dipped in cleaning solvent. Electrical parts will be damaged. (2) Clean ignition unit with rag moistened with dry cleaning solvent. 4-551