TM 9-2815-210-34-2-2 4-61. FLAME HEATER FUEL PUMP (UNCOVERED SYSTEM). a. Cleaning. FRAME 1 1. Cap electrical receptacle connection (1). 2. Plug fuel inlet (2) and outlet (3) ports. WARNING Dry cleaning solvent is flammable. Do not use near an open flame. Keep a fire extinguisher nearby when sol- vent is used. Use only in well-ventilated places. Fail- ure to do this may result in injury to personnel and damage to equipment. CAUTION Fuel pump should not be dipped in cleaning solvent. Electrical parts will be damaged. 3. Clean fuel pump with cloth dipped in dry cleaning solvent. END OF TASK 4-531