TM 9-2815-210-34-2-2 FRAME 2 1. 2. 3. Check that pulley (1) is not cracked or broken. Check that keyway in pulley is not worn. If keyway is worn or if pulley is damaged, get a new one. WARNING Dry cleaning solvent is flammable. Do not use near an open flame. Keep a fire extinguisher nearby when sol- vent is used. Use only in well-ventilated places. Failure to do this may result in injury to personnel and damage to equipment. Check that belt surface of pulley (1) is not worn and has no nicks, burrs or other damage. Fix small nicks and burrs with a fine mill file or crocus cloth dipped in dry cleaning solvent. If more repair is needed or if belt surface is worn, get a new pulley. Check that woodruff kev (2) is not worn and has no burrs. Fix small burrs with a fine mill file. If more repair is needed or if woodruff key is worn, get a new woodruff key. END OF TASK 4-477