TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2
Page 418 of 968
TM 9-2815-210-34-2-2 (2) Nozzle leakage check. FRAME 1 1. Make sure pressure gage valve (1) is open. 2. Pump handle (2). As pressure comes close to 2800 psi, check that there are no fuel drops on the nozzle (3) or that fuel does not come out as a stream. If either happens, disassemble, clean and inspect, and repair nozzle. Refer to para 4-40b, c, and d. END OF TASK 4-399