TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2
Page 41 of 968
TM 9-2815-210-34-2-2 FRAME 6 1. 2. 3. 4. 5. 6. Check that burrs with Check that Dry cleaning near an open nearby when WARNING solvent is flammable. Do not use flame. Keep a fire extinguisher solvent is used. Use only in well- ventilated places. Failure to do this may result in injury to personnel and damage to equipment. dowel pins (1) have no nicks, scratches or burrs. Fix minor a fine mill file or crocus cloth dipped in cleaning solvent. dowel pins (1) are not cracked, broken or loose. If either of two dowel pins (1) is cracked, broken or loose, pull it out using dowel pin puller. Using soft-faced hammer, tap in new dowel pin (1) until dowel pin bottoms in hole. Check that all crankcase-to-cylinder-head studs (2) are not stripped, cracked, or broken. If crankcase-to-cylinder-head studs (2) are damaged, get new ones. GO TO FRAME 7 4-22