TM 9-2815-210-34-2-2 FRAME 4 NOTE Readings must be within limits given in table 4-59. The letter L shows a loose fit. If readings are not within given limits, throw away part and get a new one. 1. Measure inside diameter of two bypass valve bores (1). 2. Measure out side diameter of two valve plungers (2). 3. Measure fit of each of two valve plungers (2) in its plunger bore (1). GO TO FRAME 5 Index Number 1 2 1 and 2 Table 4-59. Oil Cooler and Filter Housing Assembly Wear Limits Item/Point of Measurement Bypass valve bores inside diameter Valve plungers out side diameter Fit of plunger in housing bore Size and Fit of New Parts (inches) 0.8030 to 0.8040 0.8000 to 0.8010 0.0020L to 0.0040L Wear Limit (inches) 0.8050 0.7990 0.0060L 4-320