TM-9-2815-210-34-2-2 LDS-465-1/LDS-465-2 Multifuel Engine Maintenance Manual Part 2
Page 222 of 968
TM 9-2815-210-34-2-2 FRAME 5 NOTE Readings must be within limits given in table 4-45. If readings are not within given limits, throw away part and get a new one. 1. Measure free length of oil pressure regulator valve plunger spring (1). 2. Using spring tester, measure load needed to squeeze spring (1) down to 3.440 inches. 3. Using spring tester, measure solid height of spring (1). GO TO FRAME 6 NOTE: CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT IN THIS FRAME. PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR REFERENCE PURPOSES OR ARE CHECKED IN ANOTHER FRAME. TA 101245 Table 4-45. Late Model Oil Pressure Regulator Valve Plunger Spring Wear Limits Index Number 1 1 1 Point of Measurement Oil pressure regulator valve plunger spring free length Oil pressure regulator valve plunger spring load at 3.440 inches Oil pressure regulator valve plunger spring maximum solid height Size and Fit of New Parts (inches unless otherwise noted) 4.6500 24.60 to 28.60 pounds 2.8700 Wear Limits (inches) None None None 4-203