TM 9-2520-246-34-1 FRAME 5 NOTE Readings must be within limits given in table 2-52. The letter T indicates a tight fit. If readings are not within given limits, throw away part and get a new one. 1. Measure diameter of dowel pin (1). 2. Measure dowel pin bore (2). 3. Measure fit of dowel pin (1) in bore (2). GO TO FRAME 6 Index Number 1 2 1 and 2 Table 2-52. Transfer Case Dowel Pin Wear Limits Item/Point of Measurement Dowel pin diameter Dowel pin bore Fit of dowel pin in bore Size and Fit of New Parts (inches) 0.7500 to 0.7510 0.7461 to 0.7472 0.0028T to 0.0049T Wear Limit (inches) None 0.7480 0.0020T 2-213
