TM 9-2320-361-34 15-20. 115-VOLT RECEPTACLE REPLACEMENT THIS TASK COVERS: a. Removal b. Installation INITIAL SETUP APPLICABLE MODELS M185A3 and M109A3 EQUIPMENT CONDITION . Parking brake set (TM 9-2320-361-10). ● TOOLS General mechanic’s tool kit ● (Appendix B, Item 1) Tool kit, electrical (Appendix B, Item 2) REFERENCES (TM) TM 9-2320-361-10 TM 9-2320-361-20 TM 9-2320-361-34P Battery - ground cable disconnected (TM 9-2320-361-20). Safety switch in OFF position (TM 9-2320-361-10). a. Removal NOTE Tag wires, leads, terminals, and cables for installation. 1. Remove cap (1), clip (2), and cover (3) from base (5) on van wall (4). 2. Remove two screws (7) from receptacle (6) and retainers (8). 3. Pull receptacle (6) away from van wall (4). 4. Loosen three screws (10) and remove six wire leads (9) from receptacle (6). 5. Remove receptacle (6) from van wall (4). 6. Remove two retainers (8) from base (5). 1. Install two retainers (8) on base (5). 2. Install six wire leads (9) on receptacle (6) by tightening three screws (10). 3. Install receptacle (6) on two retainers (8) with two screws (7). 4. Install cover (3), clip (2), and cap (1) on base (5). b. Installation 15-74