TM 9-2320-361-34 15-18. 115-VOLT AC RECEPTACLE REPLACEMENT I THIS TASK COVERS: a. Removal b. Installation INITIAL SETUP APPLICABLE MODELS PERSONNEL REQUIRED M185A3 and M109A3 Two TEST EQUIPMENT REFERENCES (TM) Multimeter (Appendix B, Item 3) TM 9-2320-361-10 TOOLS TM 9-2320-361-20 TM 9-2320-361-34P General mechanic’s tool kit (Appendix B, Item 1) Tool kit, electrical (Appendix B, Item 2) EQUIPMENT CONDITION MATERIALS/PARTS . Parking brake set (TM 9-2320-361-10). ● Battery ground cable disconnected Gasket (Appendix F, Item 82) (TM 9-2320-361-20). Safety wire (Appendix C, Item 35) Electrical tape (Appendix C, Item 26) CAUTION Use care when removing or installing wiring harness. Excessive snagging or pulling may damage wires. NOTE Tag wires and terminals for installation. 1. Slide handle (3) on safety switch box (2) to OFF position and open cover (5). NOTE ● Perform step 2 for M109A3 vehicles. Perform step 3 for M185A3 vehicles. ● Safety wire must be attached to wires with electrical tape. 2. Loosen two screws (1) and remove two wires (4) from safety switch box (2). 3. Loosen two screws (7) and remove two wires (6) and wires (4) from safety switch box (2). 4. Attach safety wire (8) to two wires (4). 5. Remove four screws (11), receptacle (10), wires (4), and gasket (9) from van body (12). Discard gasket (9). 6. Remove two wires (4) from safety wire (8). 1. Attach safety wire (8) to two wires (4). NOTE Assistant will help with step 2. 2. Pull safety wire (8) and two wires (4) through van body (12). 3. Install new gasket (9) and receptacle (10) on van body (12) with four screws (11). 4. Remove safety wire (8) from two wires (4). NOTE Perform step 5 for M185A3 vehicles. Perform step 6 for M109A3 vehicles. 5. Install two wires (4) and wires (6) on safety switch box (2) by tightening two screws (7). 6. Install two wires (4) on safety switch box (2) by tightening two screws (1). 7. Close cover (5) on safety switch box (2) and slide handle (3) to ON position. 15-70