TM 9-2320-361-24-2 0435 00 0435 00-1 FIELD MAINTENANCE INSTRUCTIONS FOR SPECIAL PURPOSE KITS 2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL) FUEL BURNING PERSONNEL HEATER TESTING PREPARATION, FLAME DETECTOR SWITCH TEST, FUEL CONTROL VALVE TEST, FLAME DETECTOR SWITCH TEST, OVERHEAT SWITCH TEST, AND TEST EQUIPMENT REMOVAL INITIAL SETUP: Applicable Models All Tools and Special Tools General mechanic’s tool kit (item 116, WP 0469 00) Multimeter (item 51, WP 0469 00) Flowmeter Test stand Materials/Parts Two nut-assembled lockwashers (item 247, WP 0470 00) References WP 0426 00–WP 0435 00 Equipment Condition Parking brake set and wheels chocked (TM 9-2320-361-10). Battery ground cable disconnected (WP 0126 00). Fuel burning personnel heater removed (WP 0351 00).