TM 9-2320-361-24-2 0338 00 0338 00-1/2 blank FIELD MAINTENANCE INSTRUCTIONS 2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL) BLOWER MOTOR RECEPTACLE REPLACEMENT REMOVAL AND INSTALLATION INITIAL SETUP: Applicable Models M185A3, M109A3 Materials/Parts Two lockwashers (item 216, WP 0470 00) Equipment Condition Parking brake set and wheels chocked (TM 9-2320-361-10). Battery ground cable disconnected (WP 0126 00). NOTE Prior to removal, tag all lead wires for installation. REMOVAL 1. Remove two screws (3) from blower motor receptacle (4) and van wall (1). 2. Pull blower motor receptacle (4) forward and remove two screws (6), lockwashers (5), and wires (2) from blower motor receptacle (4). Discard lockwashers (5). INSTALLATION 1. Install two wires (2) on blower motor receptacle (4) with two screws (6) and new lockwashers (5). 2. Install blower motor receptacle (4) on van wall (1) with two screws (3). 3. Connect battery ground cable (WP 0126 00). 4. Release parking brake and remove wheel chocks (TM 9-2320-361-10). END OF WORK PACKAGE ~ 3 4 6 5 1 2