TM-9-2320-361-24-2 Field Maintenance Manual Volume 2 for M44A2 Series Trucks
Page 393 of 1144
TM 9-2320-361-24-2 0300 00 0300 00-1/2 blank FIELD MAINTENANCE INSTRUCTIONS 2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL) SAFETY SWITCH FUSE REPLACEMENT REMOVAL AND INSTALLATION INITIAL SETUP: Applicable Models M185A3, M109A3 Materials/Parts Two 250V fuses (item 43, WP 0470 00) Equipment Condition Parking brake set and wheels chocked (TM 9-2320-361-10). Battery ground cable disconnected (WP 0126 00). REMOVAL 1. Pull safety switch box handle (2) down to off position and open cover (4). 2. Remove two 250V fuses (3) from safety switch box (l). Discard fuses (3). INSTALLATION 1. Install two new 250V fuses (3) in safety switch box (l). 2. Close cover (4) and push safety switch box handle (2) up to ON position. 3. Connect battery ground cable (WP 0126 00). 4. Release parking brake and remove wheel chocks (TM 9-2320-361-10). END OF WORK PACKAGE 1 2 3 4 ~