TM-9-2320-361-24-2 Page 323

TM-9-2320-361-24-2 Field Maintenance Manual Volume 2 for M44A2 Series Trucks

Page 323 of 1144

TM 9-2320-361-24-2 0276 00 0276 00-1/2 blank FIELD MAINTENANCE INSTRUCTIONS 2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL) GALLON METER REPLACEMENT (M49A2C) REMOVAL AND INSTALLATION INITIAL SETUP: Applicable Models M49A2C Materials/Parts Three lockwashers (item 195, WP 0470 00) Equipment Condition Parking brake set and wheels chocked (TM 9-2320-361-10). Battery ground cable disconnected (WP 0126 00). Meter outlet tube removed (WP 0282 00). Globe valve removed (WP 0272 00). Meter-to-filter tube removed (WP 0275 00). REMOVAL 1. Remove three screws (4), lockwashers (5), and gallon meter (1) from shelf (6). Discard lockwashers (5). 2. Remove pipe (3) from elbow (2) and elbow (2) from gallon meter (1). INSTALLATION NOTE Clean all male pipe threads and wrap with antiseize tape before installation. 1. Install elbow (2) on gallon meter (1) and pipe (3) on elbow (2). 2. Install gallon meter (1) on shelf (6) with three screws (4) and new lockwashers (5). 3. Install meter-to-filter tube (WP 0275 00). 4. Install globe valve (WP 0272 00). 5. Install meter outlet tube (WP 0282 00). 6. Connect battery ground cable (WP 0126 00). 7. Release parking brake and remove wheel chocks (TM 9-2320-361-10). END OF WORK PACKAGE 1 2 6 5 4 3