TM-9-2320-361-24-1 Page 898

TM-9-2320-361-24-1 Field Maintenance Manual Volume 1 for M44A2 Series Trucks

Page 898 of 1176

TM 9-2320-361-24-1 0137 00 0137 00-2 TRANSFER CASE BREATHER MAINTENANCE (Contd) REMOVAL 1. Wipe area around transfer case breather (2) with rag. 2. Remove transfer case breather (2) from transfer case (1). CLEANING WARNING Skysol 100 solvent is combustible; DO NOT use or store near heat, sparks, flame, or other ignition sources. Use mechanical ventilation whenever product is used in a confined space, heated above ambient temperatures, or agitated. Keep container sealed when not in use. Contact with Skysol 100 may cause skin irritation. Use chemical-resistant gloves. In case of skin contact, remove any contaminated clothing and wash skin thoroughly with soap and water. Wash contaminated clothing before reuse. Eye contact may cause irritation, tearing, or blurring of vision. Use face shield or goggles when eye contact may occur. In case of eye contact, flush eyes with large amounts of water for at least 15 minutes or until irritation subsides. Inhalation may cause irritation to upper respiratory passages. DO NOT have food or drink in the vicinity. Failure to comply may result in injury to personnel. Clean transfer case breather (2) with Skysol 100. INSTALLATION 1. Install transfer case breather (2) into transfer case (1). 2. Install cab tunnels (WP 0230 00). 3 Connect battery ground cable (WP 0126 00). 4. Release parking brake and remove wheel chocks (TM 9-2320-361-10). END OF WORK PACKAGE 2 1