TM-9-2320-361-24-1 Field Maintenance Manual Volume 1 for M44A2 Series Trucks
Page 856 of 1176
TM 9-2320-361-24-1 0128 00 0128 00-2 TRANSMISSION BREATHER MAINTENANCE (Contd) REMOVAL 1. Wipe area around transmission breather hole (2) with rag. 2. Remove transmission breather (1) from transmission housing (3). CLEANING WARNING Skysol 100 solvent is combustible; DO NOT use or store near heat, sparks, flame, or other ignition sources. Use mechanical ventilation whenever product is used in a confined space, heated above ambient temperatures, or agitated. Keep container sealed when not in use. Contact with Skysol 100 may cause skin irritation. Use chemical-resistant gloves. In case of skin contact, remove any contaminated clothing and wash skin thoroughly with soap and water. Wash contaminated clothing before reuse. Eye contact may cause irritation, tearing, or blurring of vision. Use face shield or goggles when eye contact may occur. In case of eye contact, flush eyes with large amounts of water for at least 15 minutes or until irritation subsides. Inhalation may cause irritation to upper respiratory passages. DO NOT have food or drink in the vicinity. Failure to comply may result in injury to personnel. Clean transmission breather (1) with Skysol 100 solvent. INSTALLATION 1. Install transmission breather (1) on transmission housing (3). 2. Install cab intermediate tunnel (WP 0230 00). 3. Connect battery ground cable (WP 0126 00). 4. Release parking brake and remove wheel chocks (TM 9-2320-361-10). END OF WORK PACKAGE 1 3 2