TM-9-2320-361-24-1 Page 811

TM-9-2320-361-24-1 Field Maintenance Manual Volume 1 for M44A2 Series Trucks

Page 811 of 1176

TM 9-2320-361-24-1 0115 00 0115 00-1/2 blank REMOVAL NOTE • Vehicle with auxiliary power outlets and personnel heaters have two additional circuit breakers located next to horn circuit breaker. Replacement procedures are the same for all circuit breakers. • Prior to removal, tag all lead wires for installation. 1. Disconnect wires (1) and (5) from circuit breaker (2). 2. Remove two screws (4) and circuit breaker (2) from firewall (3). INSTALLATION 1. Install circuit breaker (2) on firewall (3) with two screws (4). 2. Connect wires (1) and (5) to circuit breaker (2). 3. Connect battery ground cable (WP 0126 00). 4. Lower and secure hood (TM 9-2320-361-10). 6. Check operation of horn and personel heater (TM 9-2320-361-10). 7. Release parking brake and remove wheel chocks (TM 9-2320-361-10). FIELD MAINTENANCE INSTRUCTIONS 2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL) CIRCUIT BREAKER REPLACEMENT REMOVAL AND INSTALLATION INITIAL SETUP: Applicable Models All Equipment Condition Parking brake set and wheels chocked (TM 9-2320-361-10). Hood raised and secured (TM 9-2320-361-10). Battery ground cable disconnected (WP 0126 00). END OF WORK PACKAGE ~ 1 2 3 4 5