TM-9-2320-361-24-1 Field Maintenance Manual Volume 1 for M44A2 Series Trucks
Page 717 of 1176
TM 9-2320-361-24-1 0090 00 0090 00-1 FIELD MAINTENANCE INSTRUCTIONS 2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL) WIRING HARNESS CONNECTOR REPAIR TERMINAL-TYPE CABLE CONNECTOR REPAIR, MALE CABLE CONNECTOR REPAIR, FEMALE CABLE CONNECTOR REPAIR, CONNECTOR ASSEMBLY REPAIR, AND RECEPTACLE ASSEMBLY REPAIR INITIAL SETUP: Applicable Models All References TC 9-237 Equipment Condition Parking brake set and wheels chocked (TM 9-2320-361-10). Battery ground cable disconnected (WP 0126 00). TERMINAL-TYPE CABLE CONNECTOR REPAIR 1. Strip cable insulation (1) from cable (2) to equal depth of terminal well (4). 2. Slide insulator (3) over cable insulation (1). 3. Insert cable (2) into terminal well (4) and crimp. 4. Slide insulator (3) over crimped end of terminal (5). 5 4 3 2 1