TM 9-2320-361-20 4-51. WIRING HARNESS CONNECTOR REPAIR (Contd) e. Receptacle Assembly Repair NOTE Refer to TM 9-237 for soldering instructions. 1. Strip cable insulation (21) to depth of solder wells (25) on inserts (26). 2. Slide cable ends (23) through grommet retaining nut (22) and grommet (24). 3. Place cable ends (23) into solder wells (25) and solder. 4. Slide grommet (24) over inserts (26) and press into receptacle (27) until seated. 5. Screw grommet retaining nut (22) onto receptacle (27) until seated. FOLLOW-ON TASK: Connect battery ground cable (para. 4-48). 4-81