TM 9-2320-361-20 14-16. SLAVE RECEPTACLE REPLACEMENT This task covers: a. Removal b. Installation INITIAL SETUP: APPLICABLE MODELS All MATERIALS/PARTS Six lockwashers Locknut REFERENCES (TM) TM 9-2320-361-10 TM 9-2320-361-20P EQUIPMENT CONDITION Parking brake set (TM 9-2320-361-10). Battery ground cable disconnected (para. 4-48). GENERAL SAFETY INSTRUCTIONS Battery ground cables must be disconnected before removing slave receptacle. WARNING Do not remove slave receptacle before disconnecting battery ground cables. If energized battery cables contact cab, a direct short will result and may cause injury to personnel. 1. Remove locknut (10), screw (13), ground cable (3), and two lockwashers (12) from rear battery box support hanger (11). Discard lockwashers (12) and locknut (10). 2. Remove nut (9), screw (5), and positive cables (6) and (8) from positive battery terminal (7). 3. Remove four nuts (18), lockwashers (19), and screws (20) from slave receptacle (1). Discard lockwashers (19). 4. Remove two screws (4), clamps (2), ground cable (3), and positive cable (6) from back cab panel support (16). 5. Remove two grommets (15) from cab floor (14) and pull receptacle from cab (17). b. Installation 1. Install slave receptacle (1) through cab (17) and cab floor (14). 2. Install two grommets (15) on ground cable (3) and positive cable (6) and install on cab floor (14). 3. Install slave receptacle (1) on cab (17) with four screws (20), new lockwashers (19), and nuts (18). 4. Install positive cables (6) and (8) on positive battery terminal (7) with screw (5) and nut (9). 5. Install ground cable (3) on rear battery box support hanger (11) with screw (13), two new lockwashers (12), and new locknut (10). 6. Install ground cable (3) and positive cable (6) on back cab panel support (16) with two clamps (2) and screws (4). 14-24