TM-9-2320-209-34-2-3 Page 446

TM-9-2320-209-34-2-3 Maintenance Part 3 for M44A1 and M44A2 Series Trucks

Page 446 of 592

TM 9-2320-209-34-2-3 b. Secondary Van Body Personnel Heater. (1) 24-volt test. (a) Bleeding fuel line. FRAME 1 I Soldiers 1. A and B Soldier A 2. Solder B 3. 4. 5. 6. 7. GO TO FRAME Open van doors and mount access ladder. Refer to TM 9-2320-209-10. Turn shut-off cock (1) to ON position. Tell Turn power converter selector switch (2) to Loosen line connector (3). Turn heater switch (4) to START position. Turn heater switch (4) to OFF position when from fuel line (5) . Tighten line connector (3) . 2 soldier B when ready. 24-volt position. fuel starts to drip 21-111