TM-9-2320-209-34-2-3 Page 424

TM-9-2320-209-34-2-3 Maintenance Part 3 for M44A1 and M44A2 Series Trucks

Page 424 of 592

TM 9-2320-209-34-2-3 FRAME 11 1. 2. 3. 4. 6. Take restriction electrical lead (1) out of clip (2). Hold fuel outlet (3) of fuel control valve (4) over overflow container (5). Make sure HI-LO switch (6) is in LO position. Flip control switch (7) to RUN position. Fuel pump should be pumping. Flip HI-LO switch (6) to III position. Let fuel flow into overflow container (5) for a few seconds. Let fuel flow into graduate (8) for exactly one minute. Flip HI-LO switch. (6) to LO position. Flip control switch (7) to OFF position. Place graduate (8) on a level surface. Read level of fuel (9) as shown. Level of fuel should be within limits given in table for type of fuel used. 5. Fuel Type Diesel Fuel Combat DFA DF1 DF2 Gasoline Flow Rate 6 to 8 6.5 to 8.5 6.5 to 8.5 7 to 9 cc/min) IF FUEL FLOW IS WITHIN GIVEN LIMITS, GO TO FRAME 12. IF FUEL FLOW IS NOT WITHIN GIVEN LIMITS, GET NEW FUEL CONTROL VALVE. END OF TASK 21-89