TM-9-2320-209-34-2-3 Page 420

TM-9-2320-209-34-2-3 Maintenance Part 3 for M44A1 and M44A2 Series Trucks

Page 420 of 592

TM 9-2320-209-34-2-3 FRAME 7 CAUTION 1. 2. 3. Fuel flow and leak tests must be done with fuel control valve in position it normally works in. Fuel used must be of type normally used. Failure to do this could result in a wrong measurement, causing serious damage to equipment. Join fuel supply line (1) to fuel inlet fitting (2). Using suitable electrical lead (3), join shutoff electrical lead (4) and restrictive electrical lead (5) together. Join other end of lead (3) to pin B (6) of wiring harness connector (7). Using suitable electrical lead (8), join body of fuel control valve (9) to pin A (10) of wiring harness connector (7). GO TO FRAME 8 21-85