TM 9-2320-209-34-2-3 FRAME 11 1. 2. 3. GO Align scratch marks (1) on blower assembly (2) and housing (3). Put blower assembly (2) on housing (3). Turn blower assembly (2) so studs (4) engage slots (5). Tighten nuts (6). Unscrew and take out terminal screw (7). Put on blower motor electrical lead (8). Screw in and tighten terminal screw (7). TO FRAME 12 21-61